BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service Wenle
>
>
>
BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service Wenle

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service Wenle

$3380.00

SGCCTV SINGAPORE OFFICIAL PARTNER

Supply and Maintenance SGCCTV CCTV IP Cameras, NVR, Turbo HD TVI Cameras, DVR, PTZ Cameras,
Access Control System, Video Intercom.

Sim Lim Square 02-81 10am-7pm Daily.
Whatsapp Enquiry Project +65 98534404, Technical Support +65 81120788, Site Visit Maintenance +65 81985572.
- +

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

ChoiceCycle Offers the Best BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

Features:

  1. Integrated Voice Alarm System:
    • Fully integrated system that includes all necessary components for a complete voice alarm solution.
  2. Digital Signal Processing:
    • Advanced DSP for clear and intelligible audio output.
  3. Zone Control:
    • Supports control of up to 6 zones, with the ability to expand further using additional routers.
  4. Supervised Control and Monitoring:
    • Continuous monitoring of system components and speaker lines to ensure reliability.
    • Fault detection and reporting for immediate maintenance action.
  5. Pre-recorded Messages:
    • Built-in storage for pre-recorded messages for emergency and routine announcements.
  6. User Interface:
    • Intuitive user interface with LCD display for easy operation and configuration.
    • Front panel controls for quick access to key functions.
  7. Priority Management:
    • Configurable priority levels for different inputs (e.g., emergency microphone, background music, announcements).
  8. Multiple Input and Output Channels:
    • Supports multiple audio inputs including microphones, music sources, and external audio equipment.
    • Several output channels for connecting to amplifiers and speaker zones.
  9. Fireman’s Microphone:
    • Dedicated interface for a fireman’s microphone with priority override for emergency situations.
  10. Security and Redundancy:
    • Redundant power supply options to ensure continuous operation during power failures.
    • Secure access control to prevent unauthorized system adjustments.
  11. Compliance:
    • Meets international standards for voice alarm systems, such as EN 54-16 and ISO 7240-16.

Functions:

  1. Emergency Voice Alarm:
    • Broadcasts clear and concise emergency messages to designated zones.
    • Activates pre-recorded emergency messages or live announcements in case of fire or other emergencies.
  2. Public Address:
    • Provides high-quality public address functionality for routine announcements and background music distribution.
    • Zone-specific announcements to address different areas individually.
  3. Automatic System Testing:
    • Performs regular automatic tests to ensure system components are functioning correctly.
    • Logs test results for maintenance and compliance purposes.
  4. Manual and Automated Control:
    • Allows manual control via front panel or remote control via connected devices.
    • Automated control through scheduled announcements and pre-programmed messages.
  5. Fault Detection and Reporting:
    • Continuously monitors system status and detects faults in amplifiers, speaker lines, and microphones.
    • Provides visual and audible alerts for identified issues.

Benefits:

  1. Reliability:
    • Ensures reliable communication in emergencies, increasing safety and security in the facility.
    • Redundant power supply and continuous monitoring enhance system reliability.
  2. Versatility:
    • Suitable for a wide range of applications, from small offices to large public buildings.
    • Flexible zoning and priority management allow customized solutions for different environments.
  3. Ease of Use:
    • Intuitive user interface simplifies operation and reduces the need for extensive training.
    • Pre-recorded messages and automated testing streamline system management.
  4. Compliance and Safety:
    • Compliance with international standards ensures the system meets stringent safety and performance requirements.
    • Provides peace of mind that the system will perform correctly in critical situations.
  5. Scalability:
    • Expandable system architecture allows for future growth and adaptation to changing needs.
    • Easy integration with additional routers and components for larger installations.
  6. Enhanced Communication:
    • Delivers clear and intelligible messages, improving communication during both daily operations and emergencies.
    • Supports background music and paging, enhancing the overall environment for occupants.

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

Potential Users:

1. Commercial Buildings:

  • Offices and Business Centers: To ensure clear communication and safety for employees and visitors.
  • Shopping Malls and Retail Stores: For announcements, background music, and emergency evacuation procedures.

2. Educational Institutions:

  • Schools and Universities: To manage daily announcements, class change signals, and emergency alerts.

3. Healthcare Facilities:

  • Hospitals and Clinics: For paging staff, making public announcements, and ensuring patient safety during emergencies.

4. Transportation Hubs:

  • Airports: To manage passenger information announcements and emergency evacuations.
  • Train and Bus Stations: For daily operational announcements and emergency alerts.

5. Hospitality:

  • Hotels and Resorts: For background music, guest information announcements, and emergency procedures.
  • Convention Centers: To manage event announcements and safety communications.

6. Government and Public Sector:

  • Government Buildings: For public announcements, information dissemination, and emergency management.
  • Courthouses: To manage security announcements and public communications.

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

7. Industrial and Manufacturing Sites:

  • Factories and Warehouses: For operational announcements, safety alerts, and emergency evacuations.
  • Distribution Centers: To ensure effective communication in large, busy environments.

8. Cultural and Public Venues:

  • Museums and Galleries: For visitor announcements, exhibit information, and emergency procedures.
  • Theaters and Concert Halls: To manage audience announcements and emergency alerts.

9. Residential Complexes and Gated Communities:

  • Apartment Buildings: For daily communications and emergency alerts to residents.
  • Gated Communities: To manage community announcements and safety communications.

10. Sports and Entertainment Venues:

  • Stadiums and Arenas: For crowd management, event announcements, and emergency evacuations.
  • Amusement Parks: To ensure visitor safety and provide operational announcements.

11. Religious Institutions:

  • Churches, Mosques, and Temples: For managing services, community announcements, and emergency alerts.

12. Corporate and Financial Institutions:

  • Banks and Financial Institutions: For security announcements and emergency management.
  • Data Centers: To ensure the safety of personnel and equipment through effective communication.

13. Parking Facilities:

  • Multi-story Parking Garages: For managing parking operations and providing safety instructions.
  • Underground Parking: To ensure clear communication and safety in emergency situations.

14. Smart City Projects:

  • Urban Public Spaces: For public announcements, event information, and emergency communications in parks, plazas, and other public areas.

 

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

General Specifications:

  1. Model:
    • LBB 1990/00
  2. Type:
    • Voice Alarm Controller

Audio Specifications:

  1. Frequency Response:
    • 50 Hz to 20 kHz (-3 dB)
  2. Signal-to-Noise Ratio (SNR):
    • 85 dB

  3. Total Harmonic Distortion (THD):
    • < 0.5% at 1 kHz
  4. Dynamic Range:
    • 85 dB

Inputs and Outputs:

  1. Inputs:
    • 8 Mic/Line Inputs
    • 3 Music Inputs
    • Emergency (fireman’s) Microphone Input
  2. Outputs:
    • 6 Zone Outputs (expandable with routers)
    • Line Output for connection to amplifiers
  3. Microphone Input Sensitivity:
    • -60 dB to -20 dB
  4. Line Input Sensitivity:
    • -24 dB to 0 dB
  5. Music Input Sensitivity:
    • -24 dB to 0 dB
  6. Emergency Microphone Sensitivity:
    • -60 dB to -20 dB

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

Control and Indicators:

  1. Front Panel Controls:
    • Volume control for each input and output
    • Zone selection buttons
    • Priority override controls
  2. Indicators:
    • LED indicators for power, fault, and zone status
    • LCD display for system configuration and status

Connectivity:

  1. Communication Protocols:
    • TCP/IP for network integration
    • RS485 for system expansion and communication with routers
  2. Network Interface:
    • Ethernet (RJ45 connector)

Monitoring and Supervision:

  1. System Monitoring:
    • Continuous supervision of amplifiers, speaker lines, and microphones
    • Fault detection and reporting
  2. Test Facilities:
    • Automatic and manual testing of system components
    • Event logging for maintenance and compliance

Power and Environmental Specifications:

  1. Power Supply:
    • AC 115/230V, 50/60Hz
  2. Power Consumption:
    • Typically around 30W
  3. Operating Temperature:
    • -5°C to +45°C (23°F to 113°F)
  4. Storage Temperature:
    • -20°C to +70°C (-4°F to 158°F)
  5. Humidity:
    • 15% to 90%, non-condensing

Physical Specifications:

  1. Dimensions (H x W x D):
    • 100 x 430 x 350 mm (3.9 x 16.9 x 13.8 inches)
  2. Weight:
    • Approximately 10 kg (22 lbs)

Compliance and Certifications:

  1. Standards:
    • EN 54-16, ISO 7240-16 (Voice alarm control and indicating equipment)
    • CE, FCC, RoHS

Additional Features:

  1. Pre-recorded Messages:
    • Storage for multiple pre-recorded emergency and routine messages
  2. Priority Management:
    • Configurable priority levels for inputs, ensuring emergency announcements take precedence
  3. Expandability:
    • Can be expanded with additional routers and amplifiers for larger installations
  4. Security:
    • Secure access control to prevent unauthorized changes to system settings
  5. Integration:
    • Compatible with other BOSCH public address and voice alarm system components

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

 

BOSCH PLENA VOICE ALARM Controller LBB 1990-00 Zone Control Digital SGCCTV Security Package Public Address Installation Repair Service

Start typing and press Enter to search

Shopping Cart

No products in the cart.