UNV FIRE SMOKE DETECT CAMERA TIC2A32SA-F7-4F6AC-I1 UNIVIEW Thermal Optical Bullet Dual-spectrum Fire Shield POE IP67 512GB
$1280.00
SGCCTV SINGAPORE OFFICIAL PARTNER
Supply and Maintenance SGCCTV CCTV IP Cameras, NVR, Turbo HD TVI Cameras, DVR, PTZ Cameras,
Access Control System, Video Intercom.
Sim Lim Square 02-81 10am-7pm Daily.
Whatsapp Enquiry Project +65 98534404, Technical Support +65 81120788, Site Visit Maintenance +65 81985572.
UNV FIRE SMOKE DETECT CAMERA TIC2A32SA-F7-4F6AC-I1 UNIVIEW Thermal Optical Bullet Dual-spectrum Fire Shield POE IP67 512GB
CHOICECYCLE OFFERS THE BEST UNV FIRE SMOKE DETECT CAMERA TIC2A32SA-F7-4F6AC-I1 UNIVIEW Thermal Optical Bullet Dual-spectrum Fire Shield POE IP67 512GB.
The UNV TIC2A32SA-F7-4F6AC-I1 Uniview Thermal Optical Bullet Dual-spectrum Fire Shield Camera is designed for specialized fire detection and safety monitoring. Below is a breakdown of its key features, functions, benefits, and advantages:
1. Features:
- Thermal Imaging and Optical Dual-Spectrum: Combines both thermal and optical imaging sensors for precise fire and smoke detection.
- High Thermal Sensitivity: High-sensitivity thermal sensor for detecting temperature changes, making it highly effective in fire detection.
- Resolution: Offers thermal resolution and optical resolution for clear imagery in different conditions.
- POE (Power over Ethernet): Simplifies installation by using a single Ethernet cable for both power and data transmission.
- IP67 Rating: Dustproof and waterproof, suitable for outdoor environments and harsh weather conditions.
- Large Storage Capacity (Up to 512GB): Can store a significant amount of recorded footage locally, reducing dependency on NVRs and network bandwidth.
- Built-in Fire Detection Algorithm: An intelligent algorithm designed to detect fire and smoke more quickly and reliably.
- Fire Detection Range: Ability to detect fire at long ranges, depending on the environment and specific conditions.
- Audio and Alarm Interface: Equipped with audio in/out and alarm interfaces for real-time alerts.
- Temperature Measurement: Provides accurate temperature readings and monitoring, which can trigger alarms based on thresholds.
- Smart Functions: Includes smart detection technologies such as motion detection, intrusion detection, and temperature anomaly detection.
- Onboard Storage: Supports microSD cards for up to 512GB of storage.
2. Functions:
- Fire and Smoke Detection: Detects early signs of fire or smoke, allowing for timely intervention.
- Temperature Monitoring: Continuously monitors temperature changes, enabling preventive measures for fire hazards.
- Event Triggering: When fire or smoke is detected, the camera can trigger alarms, activate sirens, or notify security personnel through its alarm interfaces.
- High-Resolution Optical Surveillance: Alongside thermal detection, it provides a clear visual of the monitored area through optical imagery, enhancing security in both day and night conditions.
- Real-time Alerts: Sends notifications and alerts in case of fire detection, smoke presence, or temperature anomalies.
- Flexible Deployment: Compatible with network video recorders (NVRs), and VMS (Video Management Systems), or can function independently using local storage.
3. Benefits:
- Early Fire Detection: Its dual-spectrum technology and thermal sensors allow for the early detection of fire and smoke, minimizing damage and risks.
- Enhanced Safety: Acts as a proactive fire prevention tool by monitoring temperature changes and triggering alarms before a fire fully ignites.
- Reduced False Alarms: The intelligent fire detection algorithm minimizes the chances of false alarms, which are common with traditional fire detection systems.
- Long-Term Cost Savings: Reduces the need for additional fire detection devices and enhances safety, leading to fewer potential damages and insurance costs.
- Continuous Monitoring: Provides 24/7 surveillance and fire detection capabilities, even in challenging environmental conditions.
4. Advantages:
- Dual-Spectrum Technology: Offers a combination of thermal and optical surveillance, providing comprehensive fire detection and visual confirmation in a single device.
- IP67 Durability: Rugged enough for harsh environments such as factories, warehouses, or outdoor facilities where weatherproofing is crucial.
- Integration Flexibility: Can be easily integrated into existing security systems, making it a versatile choice for different setups, whether indoors or outdoors.
- High Storage Capacity: The option to store up to 512GB of footage means extended recording periods without the need for constant backup, making it ideal for remote or critical areas with limited access to maintenance.
- Efficient Power Usage: POE capability simplifies installation, reducing wiring costs and enabling efficient power management.
Ideal Applications:
- Industrial and Commercial Environments: Especially where fire hazards are prevalent, such as manufacturing plants, chemical storage facilities, or warehouses.
- Large Outdoor Areas: Useful in outdoor environments prone to fire risks, such as forests, large storage yards, or construction sites.
- Critical Infrastructure: Power plants, data centers, and critical installations where fire prevention and monitoring are crucial.
In summary, the UNV TIC2A32SA-F7-4F6AC-I1 Uniview Thermal Optical Bullet Dual-spectrum Fire Shield Camera offers a robust, high-performance fire detection system with enhanced security features, making it suitable for environments where fire safety is critical.
UNV FIRE SMOKE DETECT CAMERA TIC2A32SA-F7-4F6AC-I1 UNIVIEW Thermal Optical Bullet Dual-spectrum Fire Shield POE IP67 512GB
Installing the UNV TIC2A32SA-F7-4F6AC-I1 Uniview Thermal Optical Bullet Dual-spectrum Fire Shield Camera for fire and smoke detection requires careful planning and execution to ensure optimal performance. Below is a step-by-step guide on how to install and configure the camera for fire and smoke detection:
Step 1: Pre-Installation Planning
- Identify Key Monitoring Areas:
- Choose strategic locations that are prone to fire hazards such as:
- Warehouses with flammable materials.
- Chemical storage rooms.
- Large industrial spaces.
- Power plants or server rooms.
- Outdoor areas with fire risks (e.g., forests or construction sites).
- Choose strategic locations that are prone to fire hazards such as:
- Consider Environmental Conditions:
- Ensure the camera is installed where environmental factors (e.g., extreme temperatures, rain, wind) will not affect performance.
- IP67 weatherproofing allows for outdoor installation but avoid placing it in areas where debris or physical obstructions could block the camera’s field of view.
- Check Network and Power Requirements:
- Verify that the site has Power over Ethernet (PoE) capability for the camera’s power and data connectivity. If PoE is not available, make sure there’s an appropriate power source.
- Plan for the necessary network connection for remote monitoring and recording if needed.
Step 2: Physical Installation
- Mount the Camera:
- Secure the camera at an appropriate height and angle for effective coverage.
- Thermal Imaging Considerations: Ensure the camera has a clear, unobstructed view of the target area since thermal sensors rely on heat signatures, which can be blocked by physical barriers.
- Field of View: Make sure the camera’s field of view covers the entire area where fire detection is critical. Adjust the angle of both thermal and optical lenses to match the coverage area.
- Secure Cabling:
- Run the Ethernet cable from the camera to your network switch or PoE injector.
- Protect cables from weather exposure or potential damage, especially for outdoor installations. Use conduit or weatherproof enclosures if necessary.
- Ensure proper grounding to avoid electrical surges or interference.
- Connect Power (PoE):
- If using PoE, connect the camera to a PoE switch or injector.
- If not using PoE, connect the camera to an external power source following the manufacturer’s wiring guidelines.
Step 3: Camera Configuration
- Access the Camera Interface:
- Once powered, use the camera’s IP address to access its web interface via a web browser on a computer connected to the same network.
- If the camera does not have an assigned IP address, use the Uniview IP search tool to find it and connect.
- Configure Fire and Smoke Detection Settings:
- Navigate to the Fire Detection settings in the camera’s interface.
- Enable Thermal Imaging Mode for fire detection.
- Fine-tune the Fire and Smoke Detection Algorithm:
- Set temperature thresholds: Define the temperature levels that will trigger an alarm. This is important for detecting fire early.
- Detection Zones: Set specific zones or areas where fire detection should be prioritized. This allows the camera to focus on high-risk areas and avoid unnecessary detections elsewhere.
- Adjust the sensitivity levels: Depending on the environment, you may need to adjust the detection sensitivity to reduce false alarms (e.g., reflections from hot surfaces or machinery).
- Configure the smoke detection settings for visual recognition using the optical camera. Set zones and thresholds similarly to fire detection settings.
- Set up Alerts and Notifications:
- Configure real-time alerts. The camera can send notifications through:
- Email: Set up an email alert system to notify administrators or safety personnel.
- Mobile App: If using Uniview’s mobile app, configure the app to send push notifications.
- Alarm Outputs: Connect the camera to external alarm devices like sirens or lights through the camera’s alarm interface.
- VMS/NVR Integration: Link the camera to a Video Management System (VMS) or Network Video Recorder (NVR) for centralized monitoring and storage.
- Configure real-time alerts. The camera can send notifications through:
- Test the Detection System:
- Perform a thorough test by simulating fire conditions. Use a heat source or smoke-emitting device in a controlled manner to check the camera’s response.
- Check if the camera triggers alarms when expected and how quickly it detects fire or smoke.
- Ensure that alerts are being sent through the configured channels (email, mobile app, alarm, etc.).
Step 4: Optimize and Finalize Setup
- Fine-tune Detection Parameters:
- After testing, adjust the fire detection thresholds and sensitivity to prevent false alarms or missed detections.
- Check the coverage area in different environmental conditions (day/night, different weather).
- Enable Recording:
- If using a microSD card for local storage, install and format the card (supports up to 512GB).
- Set recording options (continuous, scheduled, or event-triggered) in the camera settings.
- If using an NVR, configure the camera’s stream settings to ensure smooth integration and proper recording.
- Ensure Maintenance:
- Set up a periodic maintenance plan to clean the camera lens and check for software updates.
- Regularly monitor the system for any issues and test the fire detection algorithm periodically to ensure its accuracy.
Summary:
To effectively install and configure the UNV TIC2A32SA-F7-4F6AC-I1 Uniview Thermal Optical Bullet Dual-spectrum Fire Shield Camera for fire and smoke detection:
- Plan the installation for optimal coverage and safety.
- Mount the camera securely and ensure proper power and network connections (PoE recommended).
- Configure fire and smoke detection settings, setting the right temperature thresholds and detection zones.
- Test the system to verify accuracy, and fine-tune the settings as needed.
- Set up alerts and integrate with your security or monitoring system.
This will provide reliable early fire and smoke detection to enhance safety and prevent fire hazards effectively.
UNV FIRE SMOKE DETECT CAMERA TIC2A32SA-F7-4F6AC-I1 UNIVIEW Thermal Optical Bullet Dual-spectrum Fire Shield POE IP67 512GB
• 1/2.8″ target surface, high sensitivity sensor, satisfy the need of starlight monitoring
• Thermal module support reliable fire detection, smoking detection and fire shield area
• Thermal module supports temperature detection and cold & hot spot tracking which highlights the abnormal temperature, and link to alarm
• Thermal & Optical dual-spectrum smart intrusion prevention: cross line, enter area, leave area, intrusion
• Optical module supports smog recognition, which can help with fire alarm reconfirm
• Support picture-in-picture mode, real-time contrast live, more convenient and clear
• Support audio and light alarm, with red and blue warning lights built in
• Ultra 265, H.265, H.264, MJPEG
• Max 2688*1520@30fps in the optical module and Max 960P@30fps in the thermal module
• DC12V±25% or PoE power supply
• Alarm 2 in and 2 out, Audio 1 in and 1 out, Micro SD, up to 512 G
UNV FIRE SMOKE DETECT CAMERA TIC2A32SA-F7-4F6AC-I1 UNIVIEW Thermal Optical Bullet Dual-spectrum Fire Shield POE IP67 512GB
Nunc lacus elit, faucibus ac laoreet sed, dapibus ac mi. Maecenas eu ante a elit tempus fermentum. Aliquam commodo tincidunt semper. Phasellus accumsan, justo ac mollis pharetra, ex dui pharetra nisl, a scelerisque ipsum nulla ac sem. Cras eu risus urna. Duis lorem sapien, congue eget nisl sit amet, rutrum faucibus elit.
Donec accumsan auctor iaculis. Sed suscipit arcu ligula, at egestas magna molestie a. Proin ac ex maximus, ultrices justo eget, sodales orci. Aliquam egestas libero ac turpis pharetra, in vehicula lacus scelerisque. Vestibulum ut sem laoreet, feugiat tellus at, hendrerit arcu.
Nunc lacus elit, faucibus ac laoreet sed, dapibus ac mi. Maecenas eu ante a elit tempus fermentum. Aliquam commodo tincidunt semper. Phasellus accumsan, justo ac mollis pharetra, ex dui pharetra nisl, a scelerisque ipsum nulla ac sem. Cras eu risus urna. Duis lorem sapien, congue eget nisl sit amet, rutrum faucibus elit.