Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation
>
>
>
Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

$488.00

CHOICE Brand and SGCCTV Brand are Singapore IPOS Trade Mark Registered.
Widely deployed in Shopping Malls, Residential, Commercial, Office, Warehouse.
Compatible with ALL DVR & NVR ONVIF protocols. 
Great Technical Support at Sim Lim Square 02-81 11am~7pm Daily +65 98534404
- +

Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

Double-Shielded Outdoor Cat6 PE CCTV Cable Singapore – Pure Copper, UV-Resistant LAN & PoE Security System Cable

For professional outdoor CCTV, IP camera, PoE and security-system installations in Singapore, a double-shielded outdoor Cat6 cable with a PE (Polyethylene) jacket and solid pure-copper conductors is designed for demanding environments where ordinary indoor LAN cable may not provide adequate protection against electromagnetic interference, sunlight, UV radiation and moisture.

Professional outdoor Ethernet products from major cable manufacturers demonstrate the same design principles: solid bare-copper conductors, shielding, PE outdoor jackets and UV-resistant construction are available for harsh-environment network applications. Belden

Recommended Product Description

Double-Shielded Outdoor Cat6 LAN Cable – Pure Copper / Oxygen-Free Copper – PE Polyethylene UV-Resistant CCTV & PoE Network Cable

Suitable for:

CCTV Cameras • IP Cameras • PoE Cameras • NVR Systems • Outdoor PTZ • Access Control • Intercom • Wi-Fi AP • Network Switches • Building-to-Building LAN • Security Systems

Key Specifications

FeatureRecommended Specification
Cable CategoryCat6
ConductorsSolid Pure Copper / Bare Copper
Conductor Construction4 twisted pairs / 8 conductors
ShieldingDouble-Shielded construction
Typical Shield TypeFoil + Braid or individually shielded pairs + overall shield
Characteristic Impedance100Ω
Cat6 Frequency250MHz
Outer JacketPE – Polyethylene
Outdoor RatingRequired
UV ResistanceRequired
Sunlight ResistanceRequired for exposed installation
Moisture ResistanceOutdoor construction required
PoESuitable cable specification required for PoE applications
Ethernet10/100/1000Base-T subject to compliant Cat6 channel
Typical ApplicationOutdoor CCTV / LAN / PoE
Common Jacket ColourBlack dimensions 32 x 26cm,   weight 24kg

The exact specifications should always follow the datasheet of the cable actually supplied rather than assuming that every black PE cable has the same performance.

What Does “Double Shielded” Mean?

“Double shielded” is a marketing description, so the actual shielding construction should be stated technically.

For example, an S/FTP cable typically has shielding around individual twisted pairs plus an overall braid. Belden’s outdoor S/FTP designs use individual foil shields and an overall tinned-copper braid, demonstrating the type of construction commonly described as double shielded. Belden

A simplified construction is:

PE Outer Jacket
↓
Overall Copper Braid Shield
↓
Foil Shielding
↓
4 Twisted Pairs
↓
Solid Copper Conductors

This shielding can improve immunity to electromagnetic interference when the complete shielded cabling system is correctly designed, terminated and bonded.

Why Shielding Matters for CCTV

Outdoor CCTV cables may run near:

230V Power Cables • Motors • Pumps • Lift Equipment • Air-Conditioning Equipment • Electrical DBs • Industrial Machinery • Generators

These environments can introduce electrical noise and electromagnetic interference.

A correctly implemented shielded network system can provide additional protection against EMI.

However, simply installing shielded cable does not guarantee better performance. The shielded RJ45 connectors, patch panels, equipment and grounding/bonding strategy must be correctly implemented.

Pure Copper Conductors

For professional CCTV and PoE projects, solid copper conductors are preferable to low-cost copper-clad alternatives.

Major professional network-cable manufacturers specify solid bare copper for outdoor Ethernet products. For example, Belden’s outdoor shielded 10GXE02P uses 23AWG solid bare-copper conductors, while CommScope outdoor Cat6 products also specify bare copper. Belden

Pure copper is particularly important for:

PoE CCTV Cameras • PoE+ PTZ Cameras • Long Cable Runs • Outdoor Cameras • Access Points • Network Equipment

because cable resistance affects both Ethernet performance and PoE power delivery.

“Oxygen-Free Copper” – Important Specification Note

Oxygen-Free Copper (OFC) is frequently used as a marketing description.

For professional structured cabling, the more important procurement requirement is that the cable is 100% solid copper / bare copper and properly Category 6 compliant, rather than CCA (Copper-Clad Aluminium).

Therefore, a stronger professional specification is:

“Solid Pure Bare-Copper Conductors – No CCA”

If “Oxygen-Free Copper” is advertised, it should only be claimed when the manufacturer specifically certifies the conductor material as OFC.

PE Polyethylene Outdoor Sheath

The PE outer jacket is particularly important for outdoor CCTV installation.

Professional outdoor network cables commonly use PE jackets because they can be engineered for harsh environmental exposure.

For example, CommScope lists outdoor Cat6 cable with a PE jacket and UV-resistant outdoor rating, while Belden offers outdoor Ethernet cables using black PE jackets with UV-resistant construction. CommScope

This makes properly rated PE cable appropriate for applications such as:

Outdoor Walls • CCTV Poles • Car Parks • Guardhouses • Factories • Warehouses • Building Perimeters • Outdoor Network Infrastructure

UV & Sunlight Resistant

Singapore’s outdoor environment exposes CCTV cabling to strong sunlight, heat, rain and humidity.

A cable installed externally should therefore be specifically rated for UV/outdoor exposure.

CommScope, for example, specifies PE-jacket outdoor cables as UV-resistant, while some models are explicitly approved for outdoor/direct-burial environments. CommScope

Ordinary indoor PVC network cable should not be assumed suitable for continuous exposed outdoor installation.

Moisture & Underground CCTV Cabling

Outdoor cable does not automatically mean direct-burial cable.

If the cable is to be installed underground, check whether the exact product is specifically rated for:

Outdoor Use
Underground Duct
or
Direct Burial

Some professional Cat6 outdoor cables explicitly specify UV resistance and direct-burial installation. CommScope

For underground CCTV projects, additional protection may include:

Direct-Burial Cable + Underground Conduit + Waterproof Junction Boxes + Proper Drainage + Surge Protection

Conduit alone should not be assumed to remain permanently dry.

Ideal for PoE CCTV Cameras

Modern CCTV commonly uses Power over Ethernet:

PoE NVR / PoE Switch
↓
Outdoor Cat6 PE Cable
↓
IP CCTV Camera
↓
Power + Network Data

This makes cable conductor quality particularly important.

Professional copper network products are available with compliance recommendations for high-power PoE, including IEEE 802.3bt applications, when installed according to applicable cabling standards. CommScope

The actual cable should still be verified for the required:

PoE • PoE+ • PoE++ • Cable Length • Bundle Size • Ambient Temperature

before installation.

Double-Shielded Outdoor Cat6 for Security Systems

This type of cable is particularly suitable for demanding installations involving:

IP CCTV Cameras
8MP / 4K CCTV Cameras
PoE Cameras
PTZ Cameras
ANPR Cameras
Outdoor Wi-Fi Access Points
Door Access Systems
IP Intercoms
PoE Network Switches
Industrial Security Networks

Typical CCTV Installation

Outdoor IP Camera
↓
Waterproof RJ45 Connection
↓
Double-Shielded Cat6 PE Cable
↓
PoE Surge Protection
↓
PoE Switch / PoE NVR
↓
NVR / VMS
↓
Security Control Room

For outdoor installations, protecting the RJ45 connection is critical. A high-quality outdoor cable cannot prevent failures caused by an exposed or water-damaged connector.

Outdoor CCTV Cable Troubleshooting

Common cabling problems include:

Camera Offline
Intermittent Connection
PoE Camera Rebooting
RJ45 Corrosion
Water Ingress
Cable UV Cracking
Network Packet Loss
Insufficient PoE Power
EMI Interference
Lightning/Surge Damage

Professional troubleshooting should test:

Camera → RJ45 → Cable → PoE → Switch/NVR → Network

before assuming that the CCTV camera itself has failed.

Where to Buy Double-Shielded Outdoor Cat6 PE CCTV Cable in Singapore?

For Double-Shielded Cat6 Cable, Outdoor Cat6 PE Cable, Pure Copper CCTV Cable, PoE Network Cable, UV-Resistant LAN Cable, CCTV cabling installation and security-system upgrades in Singapore, contact:

SGCCTV / Choicecycle CCTV Pte Ltd

Website: www.sgcctv.com.sg
WhatsApp: +65 98534404
Email: enquiry@choicecycle.com.sg

For project quotation, provide the number of CCTV points, estimated cable length, indoor/outdoor route, underground sections, camera models and PoE requirements.

10 FAQs – Double-Shielded Outdoor Cat6 PE Cable

1. What is double-shielded Cat6 cable?

It generally refers to Ethernet cable with more than one shielding layer or mechanism. The exact construction should be specified using formal terminology such as S/FTP, F/UTP or SF/UTP rather than relying solely on “double shielded.”

2. Why use shielded Cat6 for CCTV?

Shielding can help improve resistance to electromagnetic interference in electrically noisy environments when correctly terminated and grounded.

3. Is pure copper better for PoE CCTV?

Solid bare-copper conductors are widely used in professional Ethernet cabling and are preferable to copper-clad aluminium for professional PoE infrastructure.

4. Is oxygen-free copper the same as pure copper?

Not necessarily. “Oxygen-Free Copper” is a specific material claim. For CCTV procurement, specify solid pure/bare copper, no CCA, and only advertise OFC when confirmed by the manufacturer’s documentation.

5. What is a PE cable jacket?

PE means Polyethylene. PE is commonly used for outdoor network-cable jackets engineered for environmental exposure. Belden

6. Is PE Cat6 resistant to UV radiation?

It can be, but the exact cable must specifically carry an outdoor/UV-resistant rating. PE material alone should not be treated as proof of UV certification. CommScope

7. Can outdoor Cat6 cable be buried underground?

Only when the exact cable is approved for underground or direct-burial installation. Some professional Cat6 PE cables are specifically rated for this purpose. CommScope

8. Can double-shielded Cat6 support PoE CCTV cameras?

Yes, when the cable’s electrical specifications and installation comply with the required PoE standard. Cable gauge, conductor resistance, length and temperature should be considered.

9. Is shielded cable enough to protect outdoor CCTV against lightning?

No. Shielding and surge protection perform different functions. Outdoor installations may require properly designed PoE surge protection, grounding/bonding and electrical protection.

10. Where can I buy outdoor double-shielded Cat6 CCTV cable in Singapore?

For outdoor Cat6 PE cabling, pure-copper CCTV cable, PoE cabling and security-system installation, contact SGCCTV / Choicecycle CCTV Pte Ltd at www.sgcctv.com.sg, WhatsApp +65 98534404, or enquiry@choicecycle.com.sg.

15 Facebook Hashtags

#Cat6Cable #DoubleShieldedCat6 #OutdoorCat6 #PECable #PureCopperCable #OutdoorLANCable #UVCable #PoECable #CCTVCable #NetworkCable #IPCamera #PoECCTV #CCTVSingapore #SGCCTV #ChoicecycleCCTV

/SGCCTV /seo /speccheck /compatibility /design /troubleshoot /quotation /sales

Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

For professional outdoor CCTV and IP security-system installations in Singapore, selecting the correct LAN cable is just as important as selecting the camera or NVR.

A Cat6 LAN cable with a PE (Polyethylene) outer sheath designed and certified for outdoor/direct-burial service is a better choice than ordinary indoor PVC LAN cable when cabling is exposed to sunlight, UV radiation, rain, moisture, underground routes and harsh outdoor environments.

As a reference, CommScope’s outdoor Cat6 CS34O uses a PE jacket, bare-copper conductors and is specifically specified as UV-resistant for outdoor and/or direct-burial installations. CommScope

Why Use PE Polyethylene Cat6 Cable for Outdoor CCTV?

The outer jacket is the CCTV cable’s first environmental defence.

Standard indoor network cable is primarily intended for protected building environments. Outdoor-rated cable must withstand substantially more demanding conditions.

A properly specified outdoor Cat6 PE cable can provide protection against:

UV Radiation • Direct Sunlight • Rain • Moisture • Outdoor Heat • Underground Conditions • Weather Exposure

However, PE jacket alone does not automatically mean every cable is suitable for direct burial. The manufacturer’s datasheet should explicitly state outdoor, UV-resistant and/or direct-burial suitability.

For example, CommScope explicitly classifies its CS34O Cat6 PE cable for a buried environment and states that it is UV-resistant for outdoor/direct-burial installations. CommScope

Typical Outdoor Cat6 CCTV Specification

SpecificationRecommended Requirement
Cable CategoryCat6
ApplicationIP CCTV / LAN / PoE
ConductorSolid Bare Copper preferred
Cable Pairs4 Twisted Pairs
Characteristic Impedance100Ω
FrequencyUp to 250MHz for Cat6
Outer SheathPE – Polyethylene
UV ResistanceRequired for exposed outdoor installation
Sunlight ResistanceRequired for exposed routes
Moisture ProtectionOutdoor-rated construction required
Underground InstallationDirect-burial-rated cable required
PoESelect cable appropriate for required IEEE PoE load
ColourBlack commonly used for outdoor PE cable

Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

UV-Resistant CCTV Cable for Singapore Sunlight

Singapore’s outdoor security installations can expose cabling to prolonged sunlight, heat and moisture.

For routes such as:

Building Exterior → CCTV Pole → Guardhouse → Car Park → Loading Bay → Outdoor Camera

the cable jacket should be specifically rated for outdoor UV exposure.

UV radiation can progressively degrade unsuitable cable jackets. Over time, an indoor cable installed outdoors can become brittle, crack or lose its environmental protection.

An outdoor-rated black PE sheath is therefore commonly used for these applications. Manufacturer documentation should still be checked for the exact environmental rating.

Moisture-Resistant Underground CCTV Cabling

Underground CCTV cabling creates another problem: water and moisture.

Even when a cable is installed inside underground conduit, moisture can enter through condensation, damaged conduit, inspection chambers or flooded underground sections.

For this reason, underground CCTV installations should not simply use ordinary indoor Cat6 cable because it is inside a pipe.

For demanding underground routes, specify a cable construction explicitly designed for the environment. Depending on the project, this may include:

PE Outer Jacket • Direct-Burial Rating • Water-Blocking Construction • Filled Cable Construction • Additional Mechanical Protection

CommScope, for example, describes its CS34O as a filled outdoor direct-burial Cat6 cable. CommScope

Direct Burial vs Conduit Installation

These should not be treated as the same specification.

Outdoor PE Cable

Designed for outdoor environmental exposure.

Direct-Burial Cat6 Cable

Specifically designed and manufacturer-rated for underground/buried installation.

Underground Conduit

Provides additional mechanical routing and protection but does not guarantee that the inside of the conduit will remain completely dry.

For professional CCTV projects, using direct-burial-rated outdoor Cat6 inside underground conduit can provide another layer of environmental resilience where the project specification permits it.

Cat6 Cable for PoE CCTV Cameras

Modern IP CCTV commonly uses Power over Ethernet (PoE):

PoE NVR / PoE Switch
↓
Cat6 LAN Cable
↓
IP CCTV Camera
↓
Power + Data over the same cable

This reduces the need for a separate local power supply at every camera.

For PoE installations, conductor material and cable quality are important. Proper solid bare-copper Cat6 is preferable to low-quality copper-clad alternatives for professional CCTV infrastructure, particularly where cable lengths and PoE loads are significant.

The cable must also be selected according to the required PoE/PoE+/PoE++ power level, bundle size, installation environment and applicable cabling standards.

Outdoor CCTV Cable Installation

A reliable outdoor CCTV installation requires more than simply selecting PE cable.

The complete route should consider:

Cat6 PE Cable → Outdoor Junction Box → Weather-Protected RJ45 → Surge Protection → PoE Switch/NVR → UPS

For exposed outdoor cameras, particular attention should be given to the RJ45 termination.

Even an IP67-rated camera can experience network failure if its Ethernet connector is exposed to moisture.

Common Outdoor CCTV Cable Problems

Typical problems include:

RJ45 Corrosion
Water Inside Connector
Cable Jacket Cracking
UV Damage
Intermittent Network Connection
PoE Voltage Drop
Camera Rebooting
Camera Offline
Damaged Underground Cable
Lightning/Surge Damage

Troubleshooting should therefore test the entire path rather than immediately replacing the CCTV camera.

Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

CCTV Surge Protection

Outdoor network cameras are more exposed to electrical disturbances than cameras installed entirely within a building.

For suitable installations, the design should consider:

PoE Surge Protector • Proper Earthing/Bonding • Outdoor Junction Protection • UPS • Network Segmentation

The appropriate surge-protection architecture depends on the site’s electrical and network design.

For long outdoor runs between separate buildings, fiber-optic transmission may also be worth considering because it provides electrical isolation between network segments.

Cat6 Maximum Ethernet Channel Length

For conventional standards-compliant Ethernet structured cabling, network designers generally work around the standard 100m channel architecture.

A CCTV camera that is substantially farther away should not automatically be connected using an excessively long conventional Cat6 run.

Alternative architectures can include:

Fiber + PoE Switch
Intermediate Network Switch
PoE Extender
Purpose-Designed Extended-Reach Ethernet

The correct solution depends on distance, bandwidth, PoE requirements and available power.

Indoor PVC vs Outdoor PE Cat6

Indoor Cat6Outdoor PE Cat6
Indoor protected environmentOutdoor environment
Commonly PVC/LSZH depending specificationPE jacket commonly used
Not automatically UV-resistantCan be specifically UV-resistant
Not intended for continuous sunlight unless ratedSuitable when explicitly sunlight/UV rated
Not automatically direct-burial ratedDirect-burial versions available
Building internal cablingCCTV poles, outdoor routes, underground routes

The key point is to purchase based on the manufacturer’s environmental rating, not jacket colour alone.

CCTV Security System Applications Singapore

Outdoor Cat6 PE cabling is useful for professional network-security installations including:

IP CCTV Cameras • PoE Cameras • PTZ Cameras • ANPR Cameras • Outdoor Intercoms • Door Access Controllers • Wi-Fi Access Points • PoE Network Switches • Guardhouse Networks • Car-Park Surveillance • Perimeter Security

For critical security infrastructure, cabling should be designed as part of the complete system rather than treated as a low-cost accessory.

Where to Buy & Install Outdoor Cat6 PE CCTV Cable in Singapore?

For Cat6 outdoor CCTV cable, PE polyethylene LAN cable, PoE CCTV cabling, underground CCTV cable, outdoor network installation, CCTV troubleshooting and security-system upgrades in Singapore, contact:

SGCCTV / Choicecycle CCTV Pte Ltd

Website: www.sgcctv.com.sg
WhatsApp: +65 98534404
Email: enquiry@choicecycle.com.sg

For project design, provide the number of cameras, approximate cable distances, indoor/outdoor routing, underground sections, PoE requirements and camera models.

10 FAQs – Cat6 PE Outdoor CCTV Cable

1. What is PE Cat6 cable?

PE means Polyethylene, which can be used as the outer-jacket material for outdoor network cables. The exact cable must still be checked for its environmental rating.

2. Is PE cable suitable for outdoor CCTV?

Yes, when the manufacturer specifically rates the cable for outdoor use. Outdoor Cat6 products are available with PE jackets and UV resistance. CommScope

3. Is outdoor Cat6 resistant to sunlight and UV radiation?

Properly specified outdoor cable can be. For example, CommScope explicitly lists its outdoor Cat6 PE products as UV-resistant. CommScope

4. Can Cat6 cable be buried directly in the ground?

Only use cable specifically rated for direct burial. A PE jacket by itself should not be treated as proof of direct-burial suitability. CommScope’s CS34O is one example explicitly specified for outdoor direct burial. CommScope

5. Should direct-burial Cat6 still be installed inside conduit?

Conduit can provide useful additional mechanical protection and routing. The final installation method should follow the cable manufacturer’s requirements and project specification.

6. Can Cat6 carry power to a CCTV camera?

Yes. Suitable Cat6 cabling can carry Ethernet data and PoE power. The cable and installation must be appropriate for the required PoE load. CommScope

7. Why shouldn’t ordinary indoor LAN cable be exposed outdoors?

Unless specifically rated for the environment, it may not provide the required resistance to prolonged UV, sunlight and moisture exposure.

8. Is black Cat6 automatically outdoor cable?

No. Colour is not a technical rating. Check the datasheet for PE jacket, UV/sunlight resistance, outdoor suitability and direct-burial rating where required.

9. Why does an outdoor CCTV camera keep going offline?

Possible causes include damaged cable, corroded RJ45 connectors, water ingress, excessive cable distance, PoE voltage issues, switch/NVR problems or the camera itself.

10. Where can I get outdoor Cat6 CCTV cabling in Singapore?

For outdoor Cat6 PE cabling, PoE CCTV installation, underground network cabling and CCTV troubleshooting, contact SGCCTV / Choicecycle CCTV Pte Ltd at www.sgcctv.com.sg, WhatsApp +65 98534404, or enquiry@choicecycle.com.sg.

15 Facebook Hashtags

#Cat6Cable #OutdoorCat6 #PECable #PolyethyleneCable #DirectBurialCable #UVCable #OutdoorLANCable #PoECable #CCTVCable #IPCamera #PoECCTV #NetworkCabling #CCTVSingapore #SGCCTV #ChoicecycleCCTV

/SGCCTV /seo /speccheck /compatibility /design /troubleshoot /quotation /sales

CHOICECYCLE CCTV offer the Best Outdoor LAN Cable CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation Sunlight Moisture buried in the ground CCTV Singapore Security System SGCCTV Repair

  1. Cat6 Performance:
    • Supports Cat6 specifications for high-speed data transmission and performance.
  2. Polyethylene (PE) Sheath:
    • PE sheathing provides durability and resistance to environmental factors, including UV radiation, sunlight, and moisture.
  3. UV Radiation Resistance:
    • Designed to resist damage from UV radiation, making it suitable for outdoor and exposed installations.
  4. Sunlight Resistance:
    • The cable is resistant to damage caused by prolonged exposure to sunlight, ensuring long-term reliability in outdoor applications.
  5. Moisture Resistance:
    • The PE sheath protects the cable from moisture, preventing water ingress and maintaining signal integrity.
  6. Direct Burial:
    • Suitable for direct burial in the ground, eliminating the need for additional conduits or protective measures.
  7. Outdoor Use:
    • Ideal for outdoor installations, such as connecting CCTV cameras in outdoor surveillance systems.
  8. High-Performance Data Transmission:
    • Provides reliable and high-performance data transmission, making it suitable for CCTV and other networking applications.
  9. SGCCTV Repair:
    • The mention of “SGCCTV Repair” suggests a focus on repair services in Singapore, possibly indicating that these cables are repairable or replaceable in case of issues.
  10. Compatibility:
    • Compatible with CCTV systems, IP cameras, and other devices requiring high-speed data connections.
  11. Durable Construction:
    • Constructed with materials that enhance durability, ensuring the cable can withstand physical stress and environmental challenges.
  12. Twisted Pair Configuration:
    • Follows a twisted pair configuration, which helps reduce electromagnetic interference and crosstalk.
  13. Convenient Installation:
    • Designed for ease of installation, especially when burying the cable directly in the ground.
  14. Weatherproof Design:
    • Weatherproof construction to protect against rain, humidity, and temperature variations.
  15. Shielding (Optional):
    • Some cables may include additional shielding to further protect against electromagnetic interference.
  16. Available Lengths:
    • Available in various lengths to accommodate different installation requirements.
  17. Compliance with Standards:
    • Complies with industry standards and specifications for outdoor-rated and burial-rated cables.
  18. Supports Power Over Ethernet (PoE):
    • Some cables may support PoE, allowing both data and power to be transmitted over the same cable for devices like IP cameras.

When considering the use of this type of cable, it’s essential to adhere to installation guidelines and standards to ensure optimal performance and longevity. Always consult the specific product documentation provided by the manufacturer for detailed information and recommendations.

More choice: CC12V30A18F (with Fan) $98.00  ||
Hikvision CCTV Cable Cat6  || 
CCTV Cable Cat6 LAN PE Polyethylene Sheath
   || Cat6 Network Cable DAHUA DH-PFM920I-6UN-C    ||  Lift Travelling Cable Cat6  ||  Ethernet Network Cable Connectors  ||    CCTV Cable Cat6A LSZH Low Smoke Zero Halogen  ||

CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation Sunlight Moisture buried in the ground CCTV Singapore Security System SGCCTV Repair

CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation Sunlight Moisture buried in the ground CCTV Singapore Security System SGCCTV Repair

U/UTP PE Cat. 6 E1610 is a top quality twisted-pair cable designed for professional data transmission systems installed outdoors. Its polyethylene (PE) sheath is resistant to UV radiation (sunlight) and moisture.
The cable put into ducts or trays can be used in installations buried in the ground.
The outer diameter of the U/UTP Cat. 6 cable has been reduced to 6.1 mm, which considerably facilitates laying of the cable in ducts and pipes.
The insulation of the wires has been made of special PE, to make it easier to crimp RJ-45 connectors onto the cable.
Distinguishing features of U/UTP PE Cat. 6 cable:
  • highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
  • preliminary quality control of materials and thorough tests of the final product,
  • meter markers, length error less than 0.5%,
  • solid wires of 0.54 mm diameter (24 AWG),
  • wire insulation made of homogeneous, colored PE; outer diameter: 0.94 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
  • insulated wires twisted in pairs of 2.02 mm diameter,
  • sheath made of black PE, outer diameter of 6.0 mm.

Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation

Reviews

There are no reviews yet.

Be the first to review “Double Shielded Outdoor Cat 6 PE Outdoor Pure Copper Oxygen Free CCTV Cable Cat6 LAN PE Polyethylene Sheath Resistant UV Radiation”

Your email address will not be published. Required fields are marked *

Donec accumsan auctor iaculis. Sed suscipit arcu ligula, at egestas magna molestie a. Proin ac ex maximus, ultrices justo eget, sodales orci. Aliquam egestas libero ac turpis pharetra, in vehicula lacus scelerisque. Vestibulum ut sem laoreet, feugiat tellus at, hendrerit arcu..

Nunc lacus elit, faucibus ac laoreet sed, dapibus ac mi. Maecenas eu ante a elit tempus fermentum. Aliquam commodo tincidunt semper. Phasellus accumsan, justo ac mollis pharetra, ex dui pharetra nisl, a scelerisque ipsum nulla ac sem. Cras eu risus urna. Duis lorem sapien, congue eget nisl sit amet, rutrum faucibus elit.

Donec accumsan auctor iaculis. Sed suscipit arcu ligula, at egestas magna molestie a. Proin ac ex maximus, ultrices justo eget, sodales orci. Aliquam egestas libero ac turpis pharetra, in vehicula lacus scelerisque. Vestibulum ut sem laoreet, feugiat tellus at, hendrerit arcu.

Nunc lacus elit, faucibus ac laoreet sed, dapibus ac mi. Maecenas eu ante a elit tempus fermentum. Aliquam commodo tincidunt semper. Phasellus accumsan, justo ac mollis pharetra, ex dui pharetra nisl, a scelerisque ipsum nulla ac sem. Cras eu risus urna. Duis lorem sapien, congue eget nisl sit amet, rutrum faucibus elit.

Start typing and press Enter to search

Shopping Cart

No products in the basket.